SYMCOM INC.

Electronic Controls
Motor Protection and Remote Monitoring Devices
Communication Modules, Software and Sensors
Voltage and Current Monitors
PumpSavers, Relays and Auxillary Products
Industrial Applications



PumpSavers, Intrinsically Safe Devices, Alternative Relays and Auxillary Products


PumpSavers

Model 777-KW/HP

The 777-KW/HP overload relay has an underpower trip rather than undercurrent. The underpower trip is desirable anytime the current vs. load is non-linear or has little change. KW/HP products should be used with all fractional horsepower motors and most motors under 3hp.

Model 77C-KW/HP

It has important advantages over current monitors in many protection applications. Any motor load that has a small or very non-linear change in current vs. load requires the use of a power monitor for underload, dry run and dead-head protection.

Model 777-TS

The 777-TS is specifically designed for use with a Subtrol-equipped Franklin submersible motor to detect high motor temperatures. It offers all other standard 777 functionality.

Model 777-AccuPower

The 777-AccuPower allows motor hp rating, full load amperage, efficiency, and power factor to be entered and will accurately calculate and display motor output power. It can be used with Symcom`s 4-20mA output module. The 777-AccuPower offers protection against single-phasing, underload, overload, phase reversal, contact failure, and current unbalance.

Informer

The Informer is a handheld diagnostic tool designed for use with single-phase PumpSaver models equipped with an infrared LED transmitter such as the 111, 233, 111 and 233 Insiders, 231 and 235. It will display real-time voltage, current, and power; dry-well and overload trip points; calibration voltage; last fault; voltage, current, and power at last fault; and highest/lowest voltage and current since last calibration.

Models 111-Insider & 231-Insider

The 111 and 231-Insider PumpSavers, designed to fit inside Franklin control boxes, protect single-phase pumps from dry-well, dead-head, jammed impeller, overvoltage, and undervoltage conditions.

Models 112-Insider & 232-Insider

The 112 and 232-Insider PumpSavers, designed to fit inside Grundfos control boxes, protect single-phase pumps from dry-well, dead-head, jammed impeller, overvoltage, and undervoltage conditions.

Models 233 & 111

The 111 and 233 PumpSavers protect 115V, 1/3-1hp and 230V, 1/3-3hp, 2 or 3-wire, single-phase pumps from dry-well, dead-head, jammed impeller, over-voltage, and under-voltage conditions.

Model 235

The 235 PumpSaver protects 5-15hp, 230V, single-phase pumps from dry-well, dead-head, jammed impeller, overvoltage and undervoltage conditions.

Model 460-15-XXX-SLD  

The Model 460-15-XXX-SLD is a microcontroller-based relay that monitors the shaft seal of a submersible pump motor. A resistive probe is installed in the seal cavity. If water leaks into the pump, the resistance measured by the probe decreases. When the resistance drops below the sensitivity setpoint, the unit will trip and the relay contacts will change state.

Model 460-15-XXX-LLS

The Model 460-15-XXX-LLS is a liquid level sensor. A probe is mounted at the desired tank level and connected to the PumpSaver®. When the probe is submersed, the PumpSaver`s output contacts will change state as soon as the debounce time expires.

Intrinsically Safe Devices

Model ISS-100

The ISS-100 intrinsically safe switch is UL 913 listed as an associated apparatus for interfacing between hazardous and non-hazardous areas. It is DIN rail or surface mountable.

Model ISS-101

The ISS-101 intrinsically safe switch is UL 913 listed as an associated apparatus for interfacing between hazardous and non-hazardous areas. It has common octal-base packaging.

Model ISS-105

The ISS-105 is a five-channel, intrinsically safe relay and pump controller. It can be used to control duplex, triplex, or quadplex pumping applications and has several useful functions and features for managing pumping systems.

Alternating Relays

Model ALT

The ALT alternating relay is used to alternate between two loads. The ALT is commonly used in duplex pumping applications to balance the runtime of both pumps.

Model ISS-105

The ISS-105 IS Super Cell is a ``smart`` five-channel intrinsically safe relay and pump controller. The IS Super Cell can be configured for a wide variety of applications including alternating or non-alternating duplex, duplex separate pump stop (SPS), triplex, and quadplex applications.

Model 50R-400-ALT

The 50R-400-ALT 400V alternating relay is used to alternate between two loads. A second float can be employed to allow both pumps to run simultaneously. A switch can be adjusted to force either of the pumps to run or be the lead pump in dual-float applications. 

Auxiliary Products

Model T-10

The T-10 is an on-delay timer with a user-selectable delay setting from 6 seconds to 10 minutes. Optional 115, 230, 460, or 600V input (460 and 600V models include high voltage relays).

Current Transformers

SymCom offers a number of footed or donut-style current transformers.

Phase 3

The Phase 3 is a line and motor sequence analyzer in one. It features audible and visual indicators and works on 60Hz and 400Hz systems from 200-600VAC.

Electronic Megohmmeter

The M-500 is an automatic, portable, battery-powered insulation tester specifically designed to be an inexpensive alternative to costly swing-needle megohmmeters.

Enclosures

SymCom offers a number of NEMA rated steel and fiberglass enclosures to house MotorSavers and PumpSavers.

Shielded Pair Cable

22AWG stranded tinned copper drain wire with polyethylene insulation – 300V @ 60°C

777 Manual Remote Reset Kit

The Manual Remote Reset Kit allows the 777 line of MotorSaver® and PumpSaver® products to be manually reset without opening the panel door.

Din Clips

DIN Clips are a simple, cost effective solution which allow MotorSaver® and PumpSaver products to be mounted onto standard DIN rail strips.

Power Perfect

Converts single-phase electrical power to three-phase power, providing a balanced sinusoidal output to any type of load.




The 777-KW/HP PumpSaver

Model ISS-101- Plug-In Style Isolated Switch
Visit our website for further information about our company       
 

Industry IDS Inc.
Association of Water Technologies International Desalination Association IRC International Water and Sanitation Centre ISTT Water Supply & Sanitation Collaborative Council
IBWA
DELEGATES
46069
Conference Sectors  Case Studies  List of Papers  Exhibition Sectors  Vendor Presentation  List of Exhibitors  Industry News  Sponsors  All Exhibitors  All Papers  Sitemap  Registration Links ]

 :: IDS Emergency Management :: IDS Packaging ::IDS Publishing / Media::IDS Healthcare Management::IDS Environment::IDS Plastics::IDS Power/Energy:: 

Industry IDS, Inc. – Online Tradeshow, Exhibition, & Buyers Guide Solutions