HPS10048-1: 300W Stepdown Regulator
300W stepdown regulator voltage or current source for DC-motor drives, halogen and LED light cable compensation
- 300W power, 3A @ 100VDC output
- 110VDC main power input
- +/-15VDC auxiliary power input
- 48VDC or 24VDC nominal output
Features include:
- Short circuit protection
- Heat sink temperature monitoring with thermal shutdown
- Current limiting
- Auxiliary power failure shutdown
- Protection against voltage feedback from DC-motor drives
Operation Modes
- Bipolar or unipolar voltage source with current limiting and negative impedance for cable compensation
- Bipolar or unipolar current source with constant voltage
- Constant voltage or current mode with on board potis
- Variable voltage or current mode with buscontrol
- Variable voltage or current mode with piggyback controller
Optional
-
Analog controller HPS1OO48-ACTRL board for mono or bipolar voltage source operation with one potentiometer as input control with power on failsafe feature
-
Digital controller HPS10048-DCTRL for all operation modes with control of all parameters over RS485 interface
Dimensions: 160 x 100 x 36 mm (w/o VG-connector)
Main power input: 110VDC, 3A max
Auxiliary power input: 70mA @ +15VDC, 40mA @ -15VDC
HPS10048 – ACTRL: Analog Controller for HPS10048-1
Piggyback analog controller board for 300W HPS10048-1 power supply
Features include:
- Allows uni- and bipolar operation of HPS10048-1 controlled by just one external potentiometer
- Provides support of all modes of operation of the HPS10048-1 board, voltage source/w current limiting and cable compensation and current source at constant voltage w/o cable compensation
- One terminal (wiper only) or three terminal (low, viper and high) potentiometer operation
- Potentiometer connections at pins Z14 (wiper) Z4 (high) and Z6 (low) of HPS10048-1 board
- Unipolar operation with either +/-5V or +/-15V control voltage range
- Bipolar operation with either +/-5V or +/-15V control voltage range
- Failsafe circuit to prevent unintentional output if the potentiometer is not set at zero at power on
- Zero point adjustment with trimmer P1
- Range limitation adjustment for either maximum current or maximum voltage with trimmer P3
- Dead band for switching the relay h-bridge only if output is zero
- Dead band adjustment with trimmer P2
- Board provides digital outputs to switch relay h-bridge as well as the power shutdown input of the HPS10048-1 board
- Control LEDs for status of digital outputs K1, K2 and power shutdown
Dimensions: 70 x 35 x 5 mm (w/o connectors)
Connections: 26 pin connector for HPS10048-1 socket
HPS 10048-DCTRL: Digital Controller for HPS10048-1
Piggyback flashmemory microprocessor controller board for 300W HPS10048-1 power supply
Features include:
- Flexible and scalable flash memory microcontroller system for field programming
- Control of all analog parameters of HPS10048-1 like, mode of operation, open circuit voltage, current limit and cable loss compensation via microcontroller
- Control of all digital outputs, PWM controller reset and shutdown and switching of relay h-bridge via microcontroller
- Control of all parameters of HPS10048-1 over RS485 interface from Windows® program for adjustment
- Storing of operation parameter sets in microprocessor integrated EEPROM over RS485 interface from Windows® program, e.g. for different cable lengths
- Measurement of output voltage and current, reverse voltage and heat sink temperature over Windows® program
- Reading of fault signal from PWM controller
- 4 LEDs to display relay h-bridge switching status (polarity), PWM reset signal, shutdown signal digital Vcc and symmetric power supply 5V for analog circuit
- 8 LEDs to display software states for diagnosis
-
Standard firmware available to control DC-motor driven tractors (voltage source mode of HPS10048-1 /w cable compensation and current limiting), halogen light (voltage source mode of HPS10048-1 /w cable compensation and current limiting), LED light (current source mode of HPS10048-1) and DC-motor driven cable reels (voltage source mode of HPS10048-1 /w cable current limiting)
-
Optional modes like active tractor brake mode to prevent the tractor from rolling backwards downhill if stopped and synchronization of cable reel and tractor
Dimensions: 70 x 35 x3 mm w/o connectors
Connections: 26 pin connector for HPS10048-1 SOCKET 10 pin flash microcontroller programming interface