Precision in laboratory and research works has always been the most critical factor in determining how useful the data is. That's why BKS & Associates has been here for more than 10 years to cater this need for all our customers.
Analyzer
Model 6308PT
1/4 DIN panel mount pH single parameter analyzer with electrode efficiency display function. Features pH linear or antilog transmitter output, hysteresis control and uninterrupted operation during pH calibration. Has one 4-20mA output, 5 relays and a RS-485 communications interface. Graphical display. 115/230V AC. CE Approved.
Model 6309PDT
pH & D.O. analyzer, 1/4 DIN panel mount IP-65 case, polarographic sensor with replaceable membranes and programmable pressure and salinity compensation. Features 2 pH and 2 D.O. fully programmable relays and one for temperature. RS-485 interface, password protected with individual ID's. 4-20 mA analog output is fully programmable, assignable & reversible. Graphical display. Tinned lead connectors. CE Approved.
Model 6309POT
pH & ORP analyzer,1/4 DIN panel mount IP-65 case. Features 2 pH and 2 ORP fully programmable relays and one for temperature. RS-485 interface, password protected with individual ID's. 4-20 mA analog output is fully programmable, assignable & reversible. Graphical display. Tinned lead connectors. CE Approved.
Benchtop
Model 1671
pH/mV/Conductivity/Temperature benchtop meter with dual LCD displays for conductivity and pH/mV/temp. Has dual analog voltage outputs for pH/mV and conductivity. Connectors are BNC, Jenco 4-Pin Jenco screw type connector for 10K thermistor ATC. Features cell adjust and 4.01/7.00/10.01 buffer select. Built in transformer for 115/230 VAC operation or battery powered via 6 AA batteries.
Model 6072
pH/mV/Temp. dual purpose bench and portable meter, microprocessor based with build in tabletop stand, LCD digital display and ATC. Features include a voltage recorder output, and both Jenco 4-Pin, 3-in-1 and BNC input connectors, electrode reference input pin and Jenco screw type ATC input. AC/DC Powered.
Model 6171
pH/mV/Temp. bench meter, microprocessor based with RS-232C IBM compatible computer interface with dual pH/mV and temperature LCD digital displays, BNC input and ATC probe uses an 8-pin DIN type input. AC/DC Powered.
Model 6173R
pH/mV/Temp benchtop meter with a very large LCD display for ease of use. Features a splash proof and rugged case ideal for schools and universities. Features EEF, Electrode Efficiency Function, multiple buffers 4.00, 4.01, 6.86, 7.00, 9.18 & 10.0 and automatic slope, buffer and electrode offset recognition. Has power down memory backup and works on 6 AA batteries or 115/230 V AC adapters. CE Approved & ISO 9001 Certified. RS-232C output.
Controller
Model 3671N
1/8 DIN panel mount pH/ORP controller with dual SPDT Hi/Lo relays, manual set points and calibration are via potentiometers. Features a voltage/recorder output and an internal pH/ORP select switch. Display is a large bright red LED. Connectors are a BNC input and spade lug screw type connector block. Meter requires a Pt-100 ATC or a simulation resistor for temperature. Power115/230A AC.
Model 3679N
1/4 DIN panel mount pH/ORP controller/transmitter in a waterproof IP-65 enclosure. Features, LCD display, dual SPDT Hi/Lo relays, manual set point adjust and pH calibration via potentiometers. For ORP there is a Zero Adjustment and pH/ORP is selectable via a shorting plug. Output is 4-20 mA current type. Connectors are a spade lug circular connector for pH+. All other connections are tinned leads to terminal blocks. Temperature compensation is a Pt-100 ATC or simulation resistor. Power 115/230V AC
Model 6503
1/4 DIN panel mount ORP controller/transmitter, microprocessor based, password protected with membrane keypad. LCD displays ORP or pH and temp. Meter has dual SPDT Hi/Lo relays, with programmable hysteresis and a reversible, isolated and programmable 4-20 mA output. Connectors are dual BNC for pH/ORP and spade lug type. ATC is 10K thermistor or simulation resistor. Power 115 / 230V AC.
Portable
Model 5003
pH/mV handheld meter with build in tabletop stand with LCD digital display. Manual temperature compensation and pH standardization calibration is via knobs and pH slope calibration is via potentiometer. Input connector is BNC type. AC/DC Powered.
Model 60
pH handheld meter with BNC, LCD display and manual temperature compensation with two point calibration via potentiometers for ease of use. Case is rugged and splash resistant. AC/DC Powered.
Model 6027
pH/mV/Temp. handheld splash proof meter, microprocessor based with LCD display of both temperature and pH. Uses Jenco 4-pin connector and 3-in-1 pH electrodes and has separate Jenco screw type ATC connector for 10K thermistor temperature probes. AC/DC Powered, 9 volt battery.
Model 6231N
Description:pH/mV/Temp. microprocessor handheld meter in splash proof case with 3 point calibration, BNC, pH/ORP connector with 8-pin DIN ATC connector. AC/DC power. CE Approved
Model 6251
Description:pH/mV/ION/Temp. microprocessor handheld meter in splash proof case, BNC pH/mV/ION connector and 8-pin DIN ATC connector. AC/DC power. CE Approved.
Transmitter
Model 691N
Description:1/8 DIN panel mount pH transmitter with calibration by potentiometers. Has a manual temperature control knob and normal transmitter output of 4-20 mA output for 0-14 pH range or in expanded mode 4-2mA can be for any 2 pH units from 0 to 14 pH. Features a large bright red LED display. Connectors are a BNC pH input and spade lug screw type connector block. 115/230V AC.
Model 692
Description:1/8 DIN panel mount pH transmitter with 4-20 mA output and calibration by potentiometers. ATC temperature control uses a Pt-100 or simulation resistor. Features a large LCD display and uses a BNC input and spade lug screw type connector block
Model 693pH
Description:2-wire 4-20 mA pH transmitter in a sealed NEMA-4 enclosure powered by 11 to 80 Volts DC. Span is fixed 0-14 pH. Connectors are BNC and tinned leads for 3-K Balco ATC sensor or simulation resistor.
Model 695pH
Description:2-wire 4-20 mA pH transmitter in a sealed NEMA-4 enclosure with an LCD display powered by 11 to 80 Volts DC. Span is selectable any 1 to 14 pH unit via internal dip switch. Connections are BNC for pH and tinned leads for 3-K Balco ATC sensor or simulation resistor.